This technical article explains how screen current behaves in tetrode RF power amplifiers operating in Class AB1 mode, demonstrating why screen-current meters provide better indication of operating conditions than plate-current meters. Using constant-current characteristic curves for the 4CX300A tetrode, the article analyzes how grid voltage drives plate and screen current variations along the operating line.